LOSSES DUE TO FRICTION IN PIPE LINES MAKE: CREATIVE LAB MODEL NO: CLFM-05
DESCRIPTION:
The setup consists of 2 pipes of different diameters, which are connected in parallel. Pressure tapings are provided on each pipe to measure the pressure losses with the help of a Differential Manometer. Control valves are fitted on each pipe, which enables to use one pipe at a time for experiment. Present set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump etc. Flow control valve And by-pass valve are fitted in water line to conduct the Experiment on different flow rates. Flow rate of water is measured with the help of measuring tank and stop watch.
EXPERIMENTATION:
To determine the losses due to fiction in pipes.
To determine the friction factor for Darcy Weisback
equation.
UTILITIES REQUIRED:
Water Supply.
Drain.
Electricity 0.5 kW, 220V AC, Single Phase.
Floor Area 1.5 x 0.75 m.
TECHNICAL DETAIL
Pipe Test Section
Dia ½”, Length: 1m, Material G.I.
Dia ¾”, Length: 1.25m, Material G.I.
Water Circulation 0.5 HP Pump, Crompton/Kirloskar/G.E makes.
Flow Measurement Using Measuring Tank with Piezometer, Capacity 25 Liters.
Sump Tank Capacity 50 Liters.
Stop Watch Electronic.
Control Panel Comprises of Standard makes On/Off Switch, Mains Indicator, etc.
Instruction manual will be provided along With the Apparatus.
Tanks will be made of Stainless Steel.
The whole set-up is well designed and arranged in a good quality painted structure.

LOSSES DUE TO PIPE FITTINGS, SUDDEN ENLARGEMENT & CONTRACTION MAKE : CREATIVE LAB MODEL NO:-CLFM-06
DESCRIPTION :
The set up consists of a ½” bend and elbow, a sudden expansion & sudden contraction fitting from 15mm to 25mm, ball valve and gate valve.  Pressure tapings are provided at inlet and outlet of these fittings under test. A differential manometer fitted in the line gives pressure loss of individual fittings. Present set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different flow rates. Flow rate of water is measured with the help of measuring tank and stop watch.
EXPERIMENTATION:
To determine loss of head in the fittings   at various water flow rates.
To measure the loss coefficient for the pipe fittings.
UTILITIES REQUIRED:
Water Supply (Initial Fill)
Drain.
Electricity 0.5 kW, 220V AC, Single Phase.
Floor Area 1.5 x 0.75 m.
 
 

TECHNICAL DETAIL
Manometer Fluid : Mercury (Hg) - 250 gm
Sudden Enlargement  : From 15mm to 25mm
Sudden Contraction: From 25mm to 15mm.
Bend : ½”
Elbow : ½”
Ball valve : ½”
Gate valve : ½”
Water Circulation: FHP Pump, Crompton make.
Flow Measurement : Using Measuring Tank with Piezometer, Capacity 25 Ltrs.
Pressure Drop Measurement: Differential Manometer
Sump Tank : Capacity 50 Ltrs.
Stop Watch : Electronic.
Control Panel Comprises of :
Standard make On/Off Switch, Mains Indicator, etc.
Instruction Manual : An ENGLISH instruction manual will be provided along with the Apparatus Tanks will be made of Stainless Steel.
The whole set-up is well designed and arranged in a good quality painted structure.
 

VENTURIMETER APPATAUS
DESCRIPTION:
The apparatus consists of two pipelines emerging out from a common manifold.  One pipe line contain a Venturimeter and other contains an Orifice. The pressure tapings from the Venturimeter and orifice meter are taken to differential manometer to measure pressure difference. The Venturimeter  connected in parallel and any one of them can be put in operation by operating valves provided at the downstream. The flow can also be regulated by these valves.  Present set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different flow rates. Flow rate of water is measured with the help of measuring tank and stop watch.
EXPERIMENTATION:
To demonstrate the use of Venturimeter meter as flow meters.
To determine co-efficient of discharge through Venturimeter  meter.
Electricity Supply: Single Phase, 220V AC, 50 Hz, 5-15 amp combined socket with earth connection.
UTILITIES REQUIRED
Water Supply (Initial Fill).
Floor Drain Required.
Floor Area Required: 1.5 x 0.75 m.
Mercury (Hg) for manometer (250 gm).
TECHNICAL DETAILS:
Venturimeter Material Clear Acrylic compatible to 1” Dia. Pipe.
Water Circulation FHP Pump, Crompton make.
Flow Measurement Using Measuring Tank with Piezometer (Capacity 25 Ltrs.)  and Electronic Stop Watch
Sump Tank Capacity 50 Ltrs.
Control Panel Comprises of: Standard make on/Off Switch, Mains Indicator, etc.
Instruction manual will be provided along with the Apparatus.
Tanks will be made of Stainless Steel.
The whole set-up is well designed and arranged in a good quality painted structure.
 

ORIFICEMETER TEST RIG MAKE : CREATIVE LAB MODEL NO:-CLFM-08
DESCRIPTION:
The apparatus consists of two pipelines emerging out from a common manifold. The pressure tapings from the orifice meter are taken to differential manometer to measure pressure difference. The Orifice meter connected in parallel and any one of them can be put in operation by operating valves provided at the downstream. The flow can also be regulated by these valves.  Present set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different flow rates. Flow rate of water is measured with the help of measuring tank and stop watch.
EXPERIMENTATION:
To demonstrate the use of Orifice meter as flow meters.
To determine co-efficient of discharge through Orifice meter.
UTILITIES REQUIRED
Electricity Supply: Single Phase, 220V AC, 50 Hz, 5-15 amp combined socket with earth connection.
Water Supply (Initial Fill).
Floor Drain Required.
Floor Area Required: 1.5 x 0.75 m.
Mercury (Hg) for manometer (250 gm).
TECHNICAL DETAILS :
Orifice meter  Orifice plate made of Stainless Steel and housing made of  Clear Acrylic compatible to 1” Dia. Pipe.
Water Circulation FHP Pump, Crompton make.
Flow Measurement  Using Measuring Tank with Piezometer (Capacity 25 Ltrs.) and Electronic Stop Watch
Sump Tank Capacity 50 Ltrs.
Control Panel Comprises of:
Standard make On/Off Switch, Mains Indicator, etc.
Instruction Manual :An ENGLISH instruction manual will be provided along with the Apparatus.
Tanks will be made of Stainless Steel.
The whole set-up is well designed and arranged in a good quality painted structure.
 
 

ROTAMETER TEST RIG MAKE: CREATIVE LAB MODEL NO: CLFM-09
DESCRIPTION:
The apparatus consists of three pipelines emerging out from a common manifold.  One pipe line contain a Venturimeter, second contains an Orifice and third pipe line contains a Rota meter. The pressure tapings from the Venturimeter and Orifice meter are taken to differential manometer to measure pressure difference. The Venturimeter, Orifice meter and Rota meter are connected in parallel and any one of them can be put in operation by operating valves provided at the downstream. Present set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different flow rates. Flow rate of water is measured with the help of measuring tank & stop watch.
EXPERIMENTATION:
To determine the co-efficient of discharged through Venturimeter and orifice meter. 
To measure discharge through Venturimeter, Orifice meter and Rota meter
To calibrate the Rotameter.
UTILITIES REQUIRED:
Electricity supply: Single Phase, 220 V AC, 50 Hz, 5-15 amp combined socket with earth connection.
Water Supply (Initial Fill).
Floor Drain required.
Floor Area Required:  1.5 m x 0.75 m.
TECHNICAL DETAILS
Rotameter: Compatible Range. Eureka makes.
Water Circulation: FHP Pump, Crompton make.
Flow Measurement: Using Measuring Tank (Capacity 25 ltrs.) and Electronic Stop Watch.
Sump Tank: Capacity 50 Ltrs.
Control Panel Comprises of: Standard make On/Off Switch, Mains Indicator, etc.
Instruction Manual: An ENGLISH instruction manual will be provided along
With the Apparatus
Tanks will be made of Stainless Steel.
The whole set-up is well designed and arranged in a good quality painted structure.
 
 

Prev   1  2  3  4  5  6  7  8   Next
ROTAMETER TEST RIG MAKE: CREATIVE LAB MODEL NO: CLFM-09    ORIFICEMETER TEST RIG MAKE : CREATIVE LAB MODEL NO:-CLFM-08    VENTURIMETER APPATAUS    LOSSES DUE TO PIPE FITTINGS, SUDDEN ENLARGEMENT & CONTRACTION MAKE : CREATIVE LAB MODEL NO:-CLFM-06    LOSSES DUE TO FRICTION IN PIPE LINES MAKE: CREATIVE LAB MODEL NO: CLFM-05    
Categories
 CHEMICAL REACTION ENGINEERING LAB
 CORE LAB
 ELECTRICAL ENGINEERING LAB EQUIPMENT’S
 ELECTRONICS ENGINEERING LAB EQUIPMENT’S
 FLUID MACHINERY LAB
 FLUID MECHANICS LAB
 HEAT TRANSFER LAB
 HYDRAULIC BENCH & ACCESSORIES
 MASS TRANSFER LAB
 MECHANICAL OPERATION LAB
 METALLURGICAL & MATERIAL SCIENCE LAB
 MOMENTUM TRANSFER LAB
 MONENTUM TRANSFER LAB
 PETROLEUM TESTING LAB
 PROCESS CONTROL & INSTRUMENTATION LAB
 PRODUCTION LAB
 REFRIGERATION & AIR CONDITIONING LAB
 STRENGHT OF MATERIAL LAB
 STRUCTURE LAB
 THEORY OF MACHINE LAB
 THERMODYNAMICS LAB
 