TECHNICAL SPECIFICATION
Body - Trinocular Head inclined at 45°.
Focusing - Both side co-axial focusing knobs.
Nosepiece - Quintuple revolving nosepiece with accurate centering & positive click stops.
Stage - Large Co-axial Mechanical Stage of size 100mm X 120mm for X-Y movement of specimens.
Illumination - Reflected light illuminator Power source 12V-100W
Objectives –
LWD Infinity Plan Semi Apo Chromatic M5X (bright field)
LWD Infinity Plan Semi Apo Chromatic M10X (bright field)
LWD Infinity Plan Semi Apo Chromatic M20X (bright field)
LWD Infinity Plan Semi Apo Chromatic M50X (bright field)
LWD Infinity Plan Semi Apo Chromatic M100X DRY
Eyepieces - WF10X /22mm (paired)
Magnification: 50x to 1000x
Analyzer/Polarizer: Set of analyzer and polarizer, 360° rotary analyzer, the polarizer & analyzer both can shift out of optical path.
Pro Cam T 5MP CMOS Color Camera having Measurement Software & Calibration Slide
1/100mm
Pixel: -5.0MP CMOS
Sensor Size: -1/2.5"
Pixels size: -2.2µm x 2.2µm
Resolution/Frame rate: -
2592x1944 (full resolution): 7FPS
1280 x 960: 27FPS, 640 x 480: 90FPS
Binning: -1x1, 2x2, 4x4
Shutter: -Electronic Rolling Shutter
Exposure Time: -0.1ms~3000ms
Sensitivity: -0.53V/Lux-sec
SNR: -44 dB
Dynamic Range: -67 dB
Spectral Range: -380-720nm (with IR-filter)
White Balance: - ROI White Balance/ Manual Temp-Tint Adjustment
Image data Format: -10bit RAW
photo format: -JPEG/BMP/PNG/RAW
Date interface: -USB3.0 (B type interface)
Operating Temperature -10°C~ 50°C
Storage Temperature -20°C~ 60°C
Operating Humidity30~80%RH
Storage Humidity10~60%RH
Power Supply DC 5V over PC USB Port
Pro Cam Capture & Measurement Software: -
Detailed Technical Specifications: -
Image Capture, Time Lapse Imaging, Video Capture, Features:
Multi-fluorescence mode
Exposure control
2D Measurement capabilities
Multi-Camera operation
Image annotation
Programmable resolution
Individual user profiles
Time-lapse
Multi-focus (Z-stacking)
Measurements: Line, Rectangle, 2&3point Circule, polygon, Angle, point, Distance b/w two
parallel lines, Dree Hand line area/Ellipses, 3 point, Center to center distance, Measurement on live
& Captured Images, Text Stamping, Annotations, Tools: Exposure control(A/M), White balance
(A/M), Counting, Annotations, Cross, & Angle dividing rulers on live & captured images,
Reference scale, time lapse imaging, Video Capturing, Edge detection, Image stitching, Z-stacking,
Calibration , Reports in MS Word & MS Excel. Image Process & Enhancement, Image format
(JPEG/BMP/RAW/PNG), Dead pixel Correction, ETC.
Metallurgical Image Analysis Software Metal Star 11.1
Grain size Analysis module:
User defined program,
User defined image enhancement & grain detection functions,
User can save program as configuration for future use,
Automatically creates Grain Boundary structure,
Planimetric method,
Hayn Linear Intercept method,
Hillard/Abrams Circle Intercept method,
Manual grain analysis,
Custom grain analysis functions,
Supports grain editing/correction,
ALA grain size (ASTM E930) analysis, Supports multiple samples
Particle size analysis module
User defined configurations with filter conditions
Image enhancement functions for particle detection
Analyze and detects particles based on defined configuration/filter
Analyze particles for length, area, circularity/elongation/roundness, Ferret length/major axis, minor axis
Can detect area, length, width, circularity/roundness/shape factor, ferret length, perimeter of various
particles of different shapes like fibre, impurities on filter etc
Can group particles identified into different buckets (user defined) by length, area, roundness,
width, circularity etc.
Supports multiple samples
Coating thickness measurement
User defined configurations with filter conditions
Image enhancement functions
Automatically identifies coating boundary
Gives MIN/ MAX/ AVG/ STD DEV of results
Can measure thickness at user selected points, all points or at user selected intervals
Supports multiple samples
Porosity analysis module
User defined image enhancement and filter functions
User can save program as configuration
User can switch to LIVE video to further analyze a feature through focus adjustment
User can group selected features into different buckets based on size and shape
Supports multiple samples
Nodularity analysis module
User defined configurations with filter conditions
Nodularity by count, Nodularity by area and Nodule density
Group results by Nodule size 1 to 8
Can export results for Phase analysis
Automatically detects Nodules based on set filter conditions
Supports multiple samples
Inclusion Analysis module
User defined configurations with filter conditions
Detects Inclusions and group by type (A, B, C, D) and further by THIN/THICK
Detection of Oversized Inclusions
Supports multiple samples
Phase Analysis module
User defined configurations with filter conditions
Can import results from Nodule/Flake analysis for Graphite/Phase report
Can detect and isolate Nodules in the image automatically or manually
Supports Phase splitting
Supports Manual point count method
User can save configurations for future use
Supports multiple samples
Flake Analysis module
User defined configurations with filter conditions
Detects and group Flakes by type A, B, C, D and E
Detects and group Flakes by size (1 to 8)
User can manually set Flake types/correction
Can export results for Phase analysis
Supports multiple samples
Dendrite Arm Spacing (for Al) Analysis module
User defined configurations with filter conditions
Image enhancement functions
For analysis on Aluminum
Supports multiple samples
Decarburization Analysis module
User defined configurations with filter conditions
Image enhancement functions
Decarburization on Steel
Supports multiple samples
2D measurements: Supports all 2D measurements like length, width, distance between points,
angle, area, perimeter, Supports tools for boundary detection like Line, Circle, Arc, Angle, Curve,
Closed curve.
Latest processing unit/operating system for analysis
Reports: Reports in PDF and Excel format
Image functions: Image rotation, gray scale, Image flipping (horizontal or vertical) Histograms,
Invert, Brightness correction
Filters Laplacian: Sobel, Blur, Noise reduction, Edge detection and enhancement filters
Subtraction, Morphology filters, Thresholding
Images: Image database, Image database filtering by date and type (grains, phases, nodularity,
inclusion etc.), Image view or Live view, Switch between image view and live view, Supports
multiple image formats like JPEG, BMP, PNG etc.
Instruction manual will be provided along with the apparatus . |