CT SCANNER
 Description: 
A CT (computed tomography) scan uses special X-ray equipment to take multiple images from different angles around the body. A computer then processes the information from the images and produces an image that shows a cross section of the area being examined. To help visualize the process, imagine looking at one end of a loaf of sliced bread. If you pull a slice out of the loaf, you can see the entire surface of that slice, from the outer crust to the center. The body is seen on CT scan “slices” in a similar way, from the outer skin to the central part of the body. The exam produces multiple slices showing multiple views of the area being examined. The “slices” can be displayed on a video monitor and saved on film for analysis.
 

LAPROSCOPIC UNIT
Technical Specifications:
Camera Image sensor: 3X1/3’’ or less Size CCD-Chip.
Pixels: 1920 x 1080
AGC: Microprocessor controlled
Lens: Integrated Optical Zoom , F= 15-31 mm
Control buttons on camera Head: 3 (2 of them freely programmable).
Video output: 2 Nos. X DVI-D output, 1 x 3G-SDI output, camera input for communication , 2 or more USB connection
 

MRI AND NMR
Description:
The NMR is our highest field MRI available and accommodates 40 and 60 mm coil sizes. The 1 T field improves resolution and sensitivity to fully characterize healthy and diseased states of the major organs. Analytical Technologies Limited’s analyzing and imaging software enable researchers to obtain a larger range of MRI images faster and more reliably. The hardware/software solution is rugged and durable, permitting novice users to acquire images using the most advanced protocols.
Advantages:
High resolution (< 80 µm) gives remarkable image quality
1 T magnetic field with high homogeneity and minimal eddy currents
Permanent magnet means no maintenance costs, no cryogens, no liquid helium required
Multiple protocols, SE, FSE, GE, and more
Small chassis means installation can be close to laboratory facilities where it is needed
Applications:
Tumor Screening and sizing
In vivo drug treatment evaluation
Relaxation analysis
Modeling of contrast agent specificity
Diabetes and obesity studies
Vascular evaluation
 

MICROPLATE SPECTROPHOTOMETER
 Description:
This is a compact microplate spectrophotometer that combines modern touch screen technology with excellent performance for UV-Vis measurements in 6- to 384-well microplates, cuvettes and in micro-volume samples with the available plate. No need to worry about limited onboard software, since it comes with full function software, ready to read and analyze data at the touch of a few buttons! For maximum versatility, it can read from 200 nm to 999 nm in 1 nm increments for single, dual and multi-wavelength measurements in end point and kinetic read methods. Spectral scanning and well area scanning add to the system’s wide-ranging application capabilities. For cell-based and other temperature sensitive assays, it 4-Zone incubation to 65 ºC reaches an even broader range of applications. A variety of data output options are available, including WiFi, Bluetooth and a USB ¬ash drive, making it a fully contained microplate spectrophotometer workstation.
 

URINE IMAGER
 Description:
Test Items: Glucose. Bilirubin. Ketone. Specific Gravity. Blood. pH. Protein. Urobilinogen Nitrite. Leukocyte. Vitamin C
Test Method: Dry strip color-developing method
Test Principle: Reflective photometry with dual-wavelength
Light Source: Cold lamp with high brightness and long lifetime
Wavelength: 520nm, 640nm, 660nm
Test Mode: Single and continuous test mode are selectable
Throughput: 120 Stripsl Hour
Test Slot: Using Sliding Slot, Easy to clean and replace, Lower the Carryover
Test Strip: Provide original strips
Display: LCD with high resolution
Language: Chinese and English are selectable
Memory: Saving more than 2000 samples results, and auto recover the results when power off during working
Interface: RS-232 232 serial porte can be connected to external printer and computer
Printer: Inner thermal pñnter can be connected to external printer
Report Format: Half quantitative and qualitative
Result Unit: SI unit and routine unit are selectable
Status Check: Auto checking the status during power on and off auto indentify the alarm.
Working Environment: Temperature: 10 C-30U ; Hurnidity: 20%RI-1-80%RH
Voltage: 85 264V, Auto adaption according to the input voltage
Power: <80W
 

Prev   9  10  11  12  13  14  15  16   Next
URINE IMAGER    MICROPLATE SPECTROPHOTOMETER    MRI AND NMR    LAPROSCOPIC UNIT    CT SCANNER    
Categories
  HIGHWAY ENGINEERING LAB
 ADVANCED COMMUNICATION LAB
 ANALYTICAL LAB EQUIPMENT
 APPLIED MECHANICS LAB
 AUTOMATION MANUFACTURING LAB
 CHEMICAL REACTION ENGINEERING LAB
 CIVIL ENGINEERING LAB
 CIVIL LAB ALL IN ONE
 CIVIL LAB EQUIPMENTS
 CONCRETE LAB
 CORE LAB
 ELECTRICAL ENGINEERNG LAB EQUIPMENTS
 ELECTRONICS ENGINEERING LAB EQUIPMENTS
 ELECTRONICS LAB
 ENVIRONMENT LAB
 ENVIRONMENTAL ENGINEERING LAB
 FLUID MACHINERY LAB
 FLUID MECHANICS LAB
 GEOLOGY LAB
 GEOTECHNICAL ENGINEERING LAB
 HEAT TRANSFER LAB
 HYDRAULIC BENCH & ACCESSORIES
 IC ENGINE LAB BL
 MANUFACTURING PROCESSES LAB
 MASS TRANSFER LAB
 MATERIAL TESTING & CONCRETE LAB
 MATERIAL TESTING LAB
 MECHANICAL OPERATION LAB
 MEDICAL LAB EQUIPMENTS
 METALLURGICAL & MATERIAL SCIENCE LAB
 MOMENTUM TRANSFER LAB
 MONENTUM TRANSFER LAB
 PETROLEUM TESTING LAB
 PHYSICS LAB
 PHYSICS LAB
 PROCESS CONTROL & INSTRUMENTATION LAB
 PRODUCTION LAB
 REFRIGERATION & AIR CONDITIONING LAB
 STRENGHT OF MATERIAL LAB
 STRUCTURE LAB
 SURVEY LAB
 SURVEYING & GEOMATICS LAB
 THEORY OF MACHINE LAB
 THERMODYNAMICS LAB
 TRANSPORTATION & HIGHWAY ENGINEERING LAB
 WORKSHOP
 
Follow us on
facebook twitter in  
 
bottom
 
Home About us Products Enquiry Contact us